Skip to content
Methods

Estimation model

Twelve sources, each with the equation family that produces it, the tier that classification implies and the measurement that would raise it. Rendered from the running engine, so this page cannot describe a method the code has moved away from.

The twelve sources
SourceFamilyEquation familyTierRoute to a higher tier
Flare — uncombusted methane
Combustion slipflare-combustion splitTier 2Direct measurement of flare combustion efficiency
Crude-tank flashing
Flashing & ventingVasquez-Beggs solution gasTier 3—
Produced-water degassing
Flashing & ventingHenry's lawTier 3—
Shuttle-tanker loading
Flashing & ventingloading factorTier 2Vapour measurement during a loading operation
Compressor rod-packing vents
Equipment lossgas-duty scaledTier 1Vent-rate measurement or component count
Compressor wet-seal vents
Equipment lossgas-duty scaledTier 1Seal-type confirmation and vent measurement
TEG reboiler vent
Equipment lossgas-duty scaledTier 1Still-column vent measurement
Equipment fugitives
Equipment losstime-in-service scaledTier 1Component count and leak-detection survey
Pneumatic devices
Equipment losstime-in-service scaledTier 1Device inventory and drive-medium survey
Cold vents / blowdowns
Equipment losstime-in-service scaledTier 1Blowdown event log
Sand handling
Equipment losstime-in-service scaledTier 1—
MEG-regeneration flash vent
Flashing & ventingconfirmed zero baseTier 3—
Every uncertain parameter

These are what the Monte-Carlo ensemble samples. The distribution shape is not a detail: over the same bounds, a triangular and a PERT on flare combustion efficiency differ by 17% in the mean slip, on a term carrying about 70% of national methane.

ParameterDistributionRangeProvenanceShape
eta_cFlare combustion efficiency — the fraction of flared methane destroyedpert0.94 – 0.98 – 0.995assumed with rangeBounded and concentrated near the mode: the mode is where the evidence points and the bounds are what cannot be excluded.
flash_ch4Methane fraction of crude-tank flash gastriangular0.15 – 0.274 – 0.4assumed with rangeBounded, with weight falling linearly to each bound. More tail weight than a PERT over the same bounds.
P_lpLow-pressure separator pressure, psiatriangular25 – 50 – 90assumed with rangeBounded, with weight falling linearly to each bound. More tail weight than a PERT over the same bounds.
pw_ventFraction of produced-water dissolved gas that reaches atmospheretriangular0.3 – 0.7 – 1assumed with rangeBounded, with weight falling linearly to each bound. More tail weight than a PERT over the same bounds.
pw_multMultiplier on the produced-water degassing estimatetriangular0.4 – 1 – 1.6assumed with rangeBounded, with weight falling linearly to each bound. More tail weight than a PERT over the same bounds.
act_multMetering uncertainty on reported Petroleum Commission volumeslognormal×÷ 1.03 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_rpUncertainty multiplier — compressor rod-packing ventslognormal×÷ 2 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_wsUncertainty multiplier — compressor wet-seal ventslognormal×÷ 2.5 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_tegUncertainty multiplier — TEG reboiler ventlognormal×÷ 1.65 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_aefUncertainty multiplier — equipment fugitiveslognormal×÷ 2 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_pneuUncertainty multiplier — pneumatic deviceslognormal×÷ 1.5 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_cvUncertainty multiplier — cold vents and blowdownslognormal×÷ 1.8 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
m_sandUncertainty multiplier — sand handlinglognormal×÷ 2.5 at 95%assumed with rangeMultiplicative. A factor of 2 means the value could plausibly be twice or half the base rate, which is how an emission-factor uncertainty is normally stated.
NextTier & completenessThe tier of each source and Scope 1 coverage